Instruction for Operating JF4001 cleaning tumbler
Equipment introduction:
JF4001 cleaning tumbler is a kind of professional equipment for surface cleaning and residue removing. In paint spraying lines and auto-body repairing systems, this kind of cleaning tumbler is usually used to clean the dust and residues from metal components, providing an excellent surface preparation for the coating/painting process.
1. Preparation for Operation
Before operating, make sure the JF4001 cleaning tumbler and surrounding environment are fit for the operation. The surrounding should has a proper ventilation system, if not, please install one. Wear protective clothes and equipment, such as mask, goggles, and rubber gloves.
2. starting up
-Automatic mode:
Secure all blockages and enable the the door switch. then press the power switch to start the motor. The tumbler will starts turning automatically and the cleaning process will begin.
- Manual mode:
Secure all blockages and then press the power switch to start the motor. Then press the manual start button which is located on the top of the tumbler. The tumbler will start turning and the cleaning process will begin.
3. Adjustment
The cleaning speed can be adjusted using the speed control knob on the left side of the machine. Increases the speed for deep cleaning and reduce the speed for lighter cleaning. The temp control knob is located on the right side and can be used to adjust the temperature of the cleaning process.
4.load
Before loading the components, make sure all removable parts are removed from the components. Secure the components on the tumbler using the secure straps. Ensure the components do not exceed the load limit of the tumbler.
5. Cleaning process
During the cleaning process, inspect the temperature and speed of the tumbler. Make any necessary adjustments during the process. When the cleaning is complete, open the door and unload the components. Check the results of the cleaning process and make any necessary adjustment.
6. Shut down
When the cleaning process is complete and all components are unloaded, press the power switch to turn off the motor and the tumbler will stop turning. Shut off all the power units and close the door.
7. maintenance
For regular maintenance and safety check, always refer to the manufacturers instruction manual.
These instructions should be followed when operating the JF4001 cleaning tumbler. Strict adherence to the instructions must be observed in order to ensure safe operation and prevent any injury to personnel.