HG/T2863—1997 Argon gas for light bulbs

HG/T 2863-1997 Argon gas for lamp bulbs This standard specifies the technical requirements, test methods, inspection rules, and product signs of argon gas for lamp bulbs. This standard applies to argon gas for lamp bulbs (hereinafter referred to as gas). This standardom does not apply to second......

HG/T 2863-1997 Argon gas for lamp bulbs

This standard specifies the technical requirements, test methods, inspection rules, and product signs of argon gas for lamp bulbs.

This standard applies to argon gas for lamp bulbs (hereinafter referred to as gas).

This standardom does not apply to secondary gas.

2 Technical Requirements

2.1 Quality Characteristics

The quality characteristics of the gas shall meet the requirements of Table 1.

Table 1 Quality Requirements

Index name Index value

Oxygen concentration, mass fraction (%) ≤0.0015

Water vapor concentration, mass fraction (%) ≤ 0.001

Non-condensable gas mass fraction (%) ≤ 0.05

Carbon dioxide mass fraction (%) ≤ 0.003

Residual chlorine mass fraction (%) ≤ 0.0005

2.2 Appearance

The gas shall be colorless and odorless.

3 Test Methods

3.1 Oxygen concentration, water vapor concentration and non-condensable gas mass fraction test

This test uses the method specified in HG/T 4810-1992.

3.2 Carbon dioxide mass fraction test

This test uses the method specified in GB/T 13480-92.

3.3 Residual chlorine mass fraction test

This test uses the method specified in GB/T 13481-92.

4 Inspection Rules

4.1 Inspection Items

The inspection items of the gas shall meet the requirements of Table 2.

Table 2 Quality Requirements

Index name Inspection items

Oxygen concentration, mass fraction (%) single batch

Water vapor concentration, mass fraction (%) each batch

Non-condensable gas mass fraction (%) each batch

Carbon dioxide mass fraction (%) each batch

Residual chlorine mass fraction (%) each batch

4.2 Inspections

Inspection shall be carried out in accordance with the provisions of HG/T 2062-1992.

4.3 Test Methods

Inspection shall be carried out in accordance with the rules for test methods in Article 3 of this standard.

4.4 Re-inspection

If the inspection results of a product do not meet the requirements of this standard, a re-inspection shall be carried out in accordance with the provisions of HG/T 2063-1992.

5 Sign of Products

The gas shall be packed in a cylinder of appropriate capacity, and the product sign shall meet the requirements of Table 3 and markings shall be easy for consumers to understand. Table 3 Product Sign Requirements

Index name Sign content

Argon gas for lamp bulbs Name, manufacturer name and business license number

Argon Mixed gas, model and batch number

Standard name and implementation date HG/T 2863-1997

Quality grade Grade 1

Net weight in unit weight kg/m3

Storage conditions

Manufacture date

Table 4 Marking requirements

Marking requirements Labels shall be affixed on the tank cover and valve outlet, and the information indicated shall be clear and affixed at a visible position.

The manufacturer shall fill in the certificate of analysis before the product is shipped, and the manual number of the certificate of analysis shall be consistent with the product batch number.

6 Packaging, Transportation and Storage

6.1 Packaging

The cylinders for packing the gas shall be made of steel materials of appropriate type and specifications, which shall meet the requirements of HG/T 2070-1997; the valve of the cylinder shall be made of bronze and shall meet the requirements of HG/T 2858-1997; the lifting ring and safety chain shall be reliable.

6.2 Transportation and Storage

6.2.1 Transportation

The valve outlet of the container for transporting the gas shall be sealed in time and securely fixed; the container can only be transported horizontally, and the container shall be protected from sunlight and rain during transportation.

6.2.2 Storage

The gas shall be stored in a place away from direct sunlight and rain, away from fire sources and easily combustible materials, and in a ventilated environment where there is no corrosion and no harmful gas generation; the container shall be protected from freezing and mechanical damage.

Put Away Put Away